While holding the shaft and trying to remove the impeller there was a part that broke off the shaft on the electrical end and I dont know what the part is and cant find it to order it. Second thought is are the pipes plumbed into the valve correct? Hi David, yes! Because all the pipes are new and no leaks have been evident, I can say with confidence that #2 is not it. Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. Do you have any tips? Hi Tom, if it is the same exact pump and pump size, that would be unusual, but if its the same horsepower, but a different pump model, that would be the simplest answer. APPLY FILTER Pumps Filters Heaters Cleaners Sanitization Automation Lighting White Goods Accessories Solar Safety i put the hose down the skimmer outlet back to the pool to fill the pipes, still nothing. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
It bubbles and their are very few ripples in the water. Looking for pool parts? Pressure reads 20. This one is 5 years old. If you like the Perflex filter, go with the Perflex EC75A, which is rated for 80 GPM, EC65A is only rated for 67 gpm. Tighten the fitting hand tight, plus 1/2 turn or so, until really snug, but not super-tight. Any ideas? I also replaced the seals. If all is well then 99% sure it would be the capacitor, weak and needs replacement. Thank you for your time, Jed. Does the LED light turn off after 60 seconds? 14 x 28 inground, water clear. Good luck ~, I have a salt water inground pool the other day i noticed my pressure is going up and down from 14psi to like 4 to 6 then back up even couple of mins. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. Air can also enter the system from low water level or a stuck skimmer weir, bringing air in from the skimmer, or from loose and leaky suction side (skimmer/main drain) valves. For a DE filter, pull out the grids and clean them off. Also could be a loose stationary switch (motor rear, 6 oclock) or a loose centrifugal switch (motor rear, dead center). Please help! Maybe the breaker is loose on the bar, or perhaps insects shorting it. I tried replacing that oring and the leak got worse somehow and it just doesnt feel like there is any pressure when tightening the 6 bolts that hold the pump and motor together. Hayward pro lx 1.5hp pump turns on for 5 seconds, shuts off, then light to moderate, white electrical smoke from pump. Typically, any dilemmas with your Hayward pool pump are likely related to either electrical or plumbing situations. I backwashed and started again and it was good for another 24 hours and the circulation stopped again and the pressure reached max. The display shows nothing as if it is not getting power. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. What is happening? Also check other possible pressure side problems, like a closed or broken exit valve on the filter, or other restrictions further down the line, up to the pool return fittings. Motor is connected to 220 volts and each phase consume 3.8 amps. Motor may still be good. The board wasnt showing anything. If symptoms continues with the filter on recirculate, you would have different problems, like restriction or obstruction in the pipes. Now that i have my new liner in and pool is filled i started adding chemicals to the pool and i went to turn the switch on and there is nothing happening with the motor. Hi Ray, the GFI breaker you replaced, is that the pump breaker? I will try to open it up tonight and report back. Before purchasing the new pump, I replaced the breaker just to be safe, but it is still throwing the new one. There are no leaks and the basket remains full with water. Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Any thoughts? How do I get the lid tight enough? My client thinks the motor was 1hp, but he really not sure. The water level is good. "description": "Hayward Pool Heater Troubleshooting Guide - how to step by step approach to determining if the water supply, gas supply, electrical supply or a component of the heater is causing the issue. Is the wire the correct size wire? It could be dead. 14mm Magnetic Spark Plug Socket, Motor will hum for a few seconds and eventually trip the breaker. If you wire 110V to a 220V motor, it will not usually run, or will only slowly turn. Also will need to have clean pump basket and a clean pool filter, to ensure adequate flow rates. Hi there. Does it only do this when vacuuming, but otherwise runs fine? Hi Mark, in looking at the owners manual https://www.intheswim.com/images/PDFs/E1964-Manual.pdf perhaps there is a minimum speed setting that is set to high, or the programming Day/Time/Speed is set up to permit high speed only? Looks clean though when I had it all apart. Any insight would be helpful. Hi Davy, Hi Jimmy, no it need not have a controller, or a timeclock, it could just have an on/off (light type) switch. I also tried it in a different place same outcome.What am I doing wrong? Once we turn the pump on it runs good for a couple of mins then then once it builds up pressure the water pressure into the pool slowly stops. I even plugged in the old pump and that too did not run? hi quick question, i have replaced the bearing for the pump but when i reassembled the pump ive noticed that if i shut the pump off and want to turn it right back on most of the time it hums like the start capactor is not working but if i shake the pump it will start up. After reinstalling, give it the full charge of DE powder, plus a little extra. If not those, it could also be a short in the motor windings, which would be a major failure, requiring a new motor. Blocked air vents and no air flow is also a possibility. This spray is not usually noticed, unless the pump has been running nearly full-head or full-speed. It hums. However after shutting it manually, the pump wouldnt start again. hayward blue essence troubleshooting . If thats not it, check the valves on the suction side (skimmer/main drain) to be sure they are not leaking air. Dec 14, 2021. Also make sure that the stationary switch copper tabs are not fused together, and that it is centered on the centrifugal switch. Please. Water at the base of the pump: 1. could be from a loose pump lid, dripping when the pump is off, 2. could be a leaking outlet pipe fitting, oozing from where water leaves the pump, and running down the sides of the volute, and dripping off the bottom, or 3. could be the shaft seal failing, behind the impeller. thoughts? Hope that helps! The cord does feel warm to the touch. Recently I started getting a loud vibration hum from my hayward pump. Pumps, Learn About Connect the hose from the pump to PUMP, the wall return pipe to RETURN, and the backwash hose connects to the WASTE port, with the use of a hose adapter and clamp. Today,I cut the pipe off where the water leak was coming from and repaired it. Select Product to Register: Step 4: Enter the registration information for your product . Home; Events. The GFI doesnt break which is where the pump is plugged into, it is just the breaker on the eletrical box that pops. If your salt system is hardwired, variations in voltage could cause the controller to go a little haywire. When turned on, it clicks in and off every few seconds. The new pump is exact same model and when not connected to system it spins and runs fine. If not, the parts internally, some parts, need replacement. If it is not, re-align your flow switch. Had a ball stuck under the skimmer basket, pump got hot and now will not turn back on. Sounds like maybe youve tried it both ways, at water level and below water level? Check the impeller and seal alignment. When I turned the pump on it is very loud and the pump is not moving water. The motor has all of the same specifications of the Hayward motor that is being replaced, what could possibly cause the motor not ot work? Hi James, I would think that could be one of the E-clips used on the bump shaft may have broken off, or an o-ring has slipped off. Took it to pool mart and they cleaned it out and said everything was fine inside it. Pool Supplies Near Me Open Now, If it does not, keep reading. Checked pump later, not running with message Drive error, heatsync overheated. If you can remove the handle, you can apply shaving cream and run the pump to see if it gets sucked in put cream around the stem and on both joints in/out of the valve. Fourth, check the motor shaft to be sure that it spins easily by hand, fifth, you can check the capacitor (for capacitance), if the motor still isnt starting. 4. remove rear motor cover, loosen screw that holds capacitor (9 oclock) and move it out of the way, so you can fit a 7/16 wrench on the rear of the motor shaft, behind the centrifugal switch. Is the pump pot filling full of water, or does it ever catch prime fully? Well, you first need to inspect it, and if the parts are broken, replace them. Everything coming in appears to be tight. Pool heaters can be the most baffling piece of pool equipment, but if you consider the proper flow of gas, water and electric, youre sure to find a solution quickly! Hi Tony, when all is good in the world, the pump basket will fill up full, and when a system is really air tight, you see no bubbles at all (through a clear pump lid), just solid water, filling the entire pump basket housing. Hi Mike, after backwashing a DE filter, you need to add DE filter powder again. On the return side, after the heater, the return valve should also move, with Spa Jets fully open and pool returns fully closed. That is the black cylinder located in the rear of the motor, at 9 oclock. Hi Rodney, well the Green wire should be ground, so that eliminates one choice. The most common cause for this is turning the valve with the pump on, or not pushing the valve handle down fully as the valve is re-positioned. If it reoccurs, you may have some pipe problems, such as a collapsed flexible PVC pipe on the skimmer. If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . Look closely at the suction-side (incoming pipes/valves, up to the strainer pot), and shut off pump, watching closely for water spray, or sometimes just a fast dribble. My Hayward h250 propane heater keeps blowing fc1 and fc2 fuses immediately after plugging in. This is a salt pool not sure if that matters in the question. Perflex filters can also leak out of the bump handle, this fix usually involves replacing the shaft o-rings. The waterfall pump should be a simple system, just a suction line and a return line (no valves? Loose connection inside the plug or socket. I am thinking it must be the age of the pump. So, it either needs a new motor, or new internal parts, or possibly a whole new pump. I noticed the on/off switch seemed loose and when I took of the end case, the male disconnect to the switch was burned out. Any ideas? It probably just needs to dry out, but breakers that trip do need to be fully turned to Off, before they can be turned back On again. Hi Matt, my first guess would be an air leak on the suction side, most typically a loose pump lid (or no o-ring lube), or loose pipe that comes into the front of the pump (or no thread sealant on the threaded fitting), or sometimes a leaky suction side valve, or low water level, stuck skimmer weir Second guess would be a broken impeller, detached from the motor shaft. Backwash several times to remove as much DE powder as possible, and then add 4 cups of DE powder for every 10 sq ft of filter surface area (see filter label if unsure). Second most common air leak on a Super Pump would be the incoming pipe fitting. Motor rate state 4 as a max amps, I dont notice a strange noise and water is flowing normal when running, I dont have a check valve in front of pump so it takes 1 minute to get prime, could you help me with a potential root cause.? have an old hayward flo lx pump and sounds like it is turning on with a click but wont start sucking the water from the pool through the pump to the filter. Internal electrical faults in the pump, such as a short circuit or improper ground, also can cause the device to draw more power than necessary and excess heating. We purchased a Hayward Pump SP3220EE and I need to know how Initially, look into the pump/strainer housing. We replaced all the seals in the pump and ran a completely new line even from the pump directly into the pool and it will not hold prime. Thought it was air leak, finally decided to check filters (pressure was 35 lbs after cleaning). I can see the water trickling in to the filter after a while, and the output becomes very limited. If the next day the chlorine level is nearly zero, shock again. I have purchased a Hayward SP 158015 Power-floLX series 1 1/2 horsepower Above Ground pool pump along with a Hayward S166T Proseries sandfilter 16 inch top mount for a 15 ft above ground proseries pool. Could that be the voltage then or is there another possibility? dhp faux leather club chair; hanna salinity tester calibration; type of, Kreepy type swimming pool cleaners - known as Suction Side Cleaners, are the simplest type of pool cleaner, and hence one of, Polaris Pool Cleaner Tune-Up Instructions I took a drive around the Beltway last weekend and opened cousin Joe's pool in Chevy Chase,, Troubleshooting Hayward Gas Heater Error Codes, Swimming Pool Covers: The Good, The Bad, The Ugly, Pool Cleaner Tune-Up Kreepy Type Pool Cleaner repair, https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual, https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS. Press and hold the diagnostic button for 3 to 5 seconds. Air could also be entering the pump from the threaded pipe or union that is attached to the inlet port, which may also spray or drip when the pump shuts off. We are headquartered in Valley Stream, New York, just outside of New UNK the , . I replaced my old hayward maxflow pump with the new variable speed sp2670020vsp. outlet still on. Thats good such frozen motors are common in the spring. Products, View Contains 13 high-performance titanium electrode plates that are coated with a special formula that combines the most corrosion-resistant metal on earth, iridium and ruthenium, to ensure extended cell life and increased chlorine production efficiency. What is the problem. The cell amperage is above the maximum limit. Hi, use a wrench on the rear of the shaft (or large flathead),to work the shaft back and forth until it spins freely. Loose pump lid, filter lid, air bleeder, probably around the filter, allowing the filter to drain down, and fill with air. Get support by contacting us online, hayward Step 2: Select your product type. Thank you so much, Also check that wires are tightly attached, at breaker, timer and pump. Clear all debris from the heatsink (page 36) on the bottom of the drive. "height": "219",
Please help! So my Hayward melted the whole left sided plastic shrouds. I am getting a CEL code and the heater will not run. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Regardless, after wiring it up (we did the hot on the bottom and neutral on the top), I put water in the basket and turned on the pump. Mine hums and then trips the breaker. Just push the red button back in. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. to turn off the timer. Filter. Pump lid not on tight, gasket not lubed, or not positioned properly (superpump) Hello, Im having an issue where my variable speed pump is pushing de back into the pool however it only does this when its running at a lower RPM and does not exhibit this issue when running at priming speed or a higher RPM. Missing push-pull valve o-rings, DE powder getting inside of the grids however thats something notable and the fact that it only does it on Low Speed, also unique. Or, 2). I just replaced a Hayward 2 hp SP2615X20 that started making a loud noise while still pumping, so I figured the bearings or something were gone, with a Hayward SP3015X20AZ 2 hp. Theory and practice | Find, read and cite all the research you need on ResearchGate Chapter 1: The Evil Emperor's Son. New motor sounds like the thermal overload switch (located at 12 oclock in the rear of the motor) is shutting off the motor, which is usually not a good sign, and mostly means the pump is on its way out. If they wont or cant fix it, call a electric motor repair shop to visit, or pull the pump and take it to them for service, or attempt the (easy) repair yourself. Seems to take away the point of getting a variable speed pump if we have to run it on high all the time. If there is air in the basket it hums away loudly and sucks great to prime and fill the basket (the saltwater thing even appears to be working). Or, it could be that the motor is cavitating, and restricting the return side somewhat may balance the flow, if you have a valve or bypass arrangement, or can plug one of the returns, for testing. Could also be a vibration noise, or rocks/pebbles in the pump basket. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. American Freight San Antonio, You dont have a saltwater pool do you? Just be sure to buy the correct seal for your make/model pump, for the Powerflo Matrix pump, thats here: https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c SPX1250XZ2C. Also that some circuit breakers used can create such noise as to cause problems with this error message. from If the flow is normal however, it could be a bad flow switch or pressure switch. Electrician was here at least 4 times and did not find anything. Any suggestions? Hey John 2. Hi Yolanda, also a great question first plug something else like a hair dryer or lamp into the outlet, to be sure its supplying 115V properly (or use a test meter). I hope new filters fix the problem!!! I just have a problem with the motor pump, I turn ON Saturday morning and left all day working, On Sunday morning I try to turn on the pump but it only make a noise but water dont flow then it stop working, then on Monday do the same thing it only make noise for 3 minutes then it stop working. Replace the seal in the same orientation as you removed it, and reassemble. If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. I just want to clarify..we had a problem with the fuse box and its just been changed. I only rotated the one piece how can the screws not go right back in? I have 2 extension cords running to plug it in. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. So it seems its changing speeds from slow to normal or is shutting off and immediately turning back on. The water does not flow when the pump is turned on. In cases such as this, it is often wise to get things going sooner, and replace the pump (or motor) now, and sort out the money later unless you are able to cover the pool with a winter cover, to block the sun, or load up the pool with lots and lots of chlorine and daily brushing/skimming both of which could sustain the water for up to 2 weeks, in most cases. If you have an electric motor repair shop in town, they may have it in stock, or order it online. Is it possible pump too small for AV60 filter? The pump was about 13 years old. My first thought is that the breaker may be too small for the amount of amps needed to start each piece of equipment. In the last couple weeks it started getting louder at various times throughout the day. Hi Mike, pumps are too hot to touch normally, running at 140 or so. So, if you replaced the handle assembly and valve, aka the Key Assy, item SPX0714BA, and water is still coming out of the backwash line? Im being advised by an electrician that my Hayward pump has a dead short in it. It did never tripped during program. Any idea what could be the culprit? Thats all I can think of now. what could be the issue? Hi Brian, is this a DE filter? Mt Tercer nivel ( dos elevadores ) 3 recamaras, Depto: 4 recamaras Salita de visitas Salita de TV 2, Diseado por travel organiser personalised. Automatic restart is 2 minutes after the error condition is corrected and the limit string closes. HI Alberto, if a motor is overheating, it normally takes about 15-20 minutes, and then the thermal overload switch, located in the rear of the motor, will trip, shutting off the pump for about 15-20 minutes, until it is cool enough to start again, on its own. If you're researching Blue Essence, we're more than happy to help you figure out the best solution for replacing, upgrading, or repairing your system. I have a thermal switch on it,thank goodness or the motor would probably be fried. The hot side goes into the timer's N0-3 and common into com-1. the motor makes humming sound but nothing happened, then the motor became burning hot. A click on the outlet you say? Hi Kathy, the clicking could be the start switch in the rear of the motor, not fully disengaging. If you do have power at the motor terminal board, look for loose wires, crimped wires, broken wires Suspect the capacitor (black cylinder located at 9 oclock), these can be tested, or if looks burnt, bulged, crack or leaking, replace with the exact same MFD number capacitor. Could this be my problem? This worked well until about 4 years ago, when I replaced it with a similar pump, a Hayward sp2607x10. Timer 1 comes on at 10:30 at 1450rpms and runs to 3:30. You can pull out the plunger and inspect, and see how it fits the valve body, at the top, should contact all sides, and be lubed well, twice per year. Diagrams, Pool Is there any other switch? If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. 9,000 gallon in ground pool. It can also happen when voltage is incorrect (too high or too low), or when wires are shorting out, or in some cases, very hot weather and direct sunshine and other nearby sources of heat. Cracked Seal on Case Completely Dry inside. The motor eventually started. Inspect and clean your cell. A check valve could also be a solution, but a Drain King is different, they are used to pressure lines, for blowing out clogged drains usually, but also useful to pressurize the suction manifold to look for air leaks, or for priming a pump that has issues catching prime. Look closely at the centrifugal switch on the rear of the shaft, to be sure its tight and is not missing parts (like the springs), engage the switch by hand (power off), to be sure that the stationary switch (located at 6 oclock) is disengaging, or the two copper tabs separate. This code will display if 120V polarity is reversed, low voltage is detected, or if the ground path is not sufficient. "primaryImageOfPage": {
The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. My pump keeps overheating and shutting off. I just replaced my pump/motor at the start of this swimming season. Reprime the pump again, open water valves and test. Happens all the time to pool pumps, and the way to un-stick it is to do some disassembly in the rear of the motor, to get a wrench on the slotted rear of the motor shaft, and work the shaft back and forth for a minute, to break the rust seal, and get the shaft to turn again. Do you have to find the pump up with water before turning it on? Ill look up the Drain King, is that something like a check valve? So, I dont think you can use this motor, (sorry), unless you are able to add another 110V wire, and run both connected wires from a Double pole breaker. 25 LibriVox About. Hi Stacey, the build-up of pressure usually means that the filter is clogged, as you likely know. Was the filter multiport valve replumbed also? My guess is they would pronounce it DOA, but may find something interesting, or may find no problem at all, which would lead you to suspect the wiring, breaker, timer the source of power. Ive checked the voltage coming in before the breaker and after the breaker, (at the motherboard location), replaced the breaker just to be safe, but still, overheats. Your chlorine generator is still producing chlorine at the moment, which is a good thing. All Rights Reserved. Inspect for any damage to wires or wire casing. This morning I decided to open fully all valves while pump was on low and no flow was detected. The pump works and will pump out whatever water is in the line, but wont prime and suck the water from the pool. Hi Mary, flocculents usually produce a fluffy precipitate that is vacuumed to waste, because it clogs ups the filter. Heater wont ignite when water temp is above 80 degrees. Worn bearings can also create enough heat to trip the switch. It was probably spouting water several feet in the air, which soaked the motor, and popped a breaker? Found this blog, followed the instructions by removing the capacitor and thermal overload, turnied the shaft with a 7/16s. The print and bearings were replaced. All Make sure it is fully pushed into the panel, and the wires are tightly connected, which they likely are. Upon restart, pump sounds horrible, like pumping rocks. I have a Hayward pool pump/filter, model SP3220EE. Well, the good news is you are at the right spot and youre definitely not alone. Hi Marsha, Ive had this question a lot this year. If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more).